Highest Scrypt output
35 Gh/s per unit leads Bitmain's Scrypt line-up.
Bitmain
The fastest Scrypt miner in the L11 line: 35 Gh/s of Litecoin and Dogecoin hashrate in a 2U hydro chassis.
Need 10, 50 or 100+ units? Request volume pricing.

The Bitmain Antminer L11 Hyd 2U is a hydro-cooled Scrypt miner rated at 35 Gh/s and 5,775 W, an efficiency of 165 J/Gh. It merge-mines Litecoin and Dogecoin and connects to a facility coolant loop rather than carrying its own radiator.
Scrypt mining is dominated by Litecoin–Dogecoin merge mining, where a single machine earns on both chains simultaneously from the same work. The L11 Hyd 2U is currently the highest-output unit in that category, which matters because Scrypt hashrate is far scarcer than SHA-256 hashrate.
As a shared-loop 2U unit it is intended for facilities that already run hydro rows. Operators without a loop should look at the self-contained 6U variant instead, which carries its own radiator.
| Manufacturer | Bitmain |
|---|---|
| Model | Antminer L11 Hyd 2U |
| Algorithm | Scrypt |
| Hashrate | 35 Gh/s |
| Power consumption | 5775 W |
| Efficiency | 165 J/Gh |
| Cooling | Hydro (liquid) cooling |
| Form factor | 2U rack-mount hydro unit |
| Chip / platform | Not published — confirm with sales |
| Mineable coins | LTC, DOGE, BEL |
| Input voltage | Not published — confirm with sales |
| Network interface | Ethernet (RJ45) |
| Dimensions | Not published — confirm with sales |
| Weight | Not published — confirm with sales |
| Noise level | ≈50 dB |
| Release date | December 2025 |
The L11 Hyd 2U mines Scrypt coins: Litecoin (LTC) and Dogecoin (DOGE) via merge mining, plus smaller Scrypt chains such as Bellscoin.
Merge mining means one unit of Scrypt work is submitted to both the Litecoin and Dogecoin networks, so revenue accrues in two assets at once — a meaningful diversification benefit compared with single-chain mining.
The Bitmain Antminer L11 Hyd 2U is rated at approximately 5775 W at the wall. Electricity is usually the largest recurring cost of running it, so estimate the draw at your own rate before committing to a deployment.
Based on a rated draw of 5775 W at 100% uptime: power in kW × 24 × your rate. Real consumption varies with firmware, ambient conditions and uptime.
The Bitmain Antminer L11 Hyd 2U is a liquid-cooled unit. It has no onboard fans for the hashboards: heat is carried away by coolant circulating through a cold plate and must be rejected by external infrastructure — typically a dry cooler, cooling tower or plate heat exchanger sized for the site's total heat load.
A hydro deployment needs a closed loop with pumps, manifolds, filtration, quick-disconnect couplings and coolant treatment. Plan for water quality control and leak detection, and match manifold sizing to the number of units per row so flow rate stays inside the manufacturer's window.
The payoff is density and acoustics. Hydro units run far quieter than air-cooled miners, tolerate higher ambient temperatures, and let operators pack substantially more hashrate into the same floor area. Heat recovery is also practical, because the rejected heat leaves the machine as warm water rather than hot air.
35 Gh/s per unit leads Bitmain's Scrypt line-up.
Litecoin and Dogecoin merge mining generates rewards on both networks from the same hashrate.
About 50 dB with no hashboard fans, and only 2U of rack height per machine.
How the Bitmain Antminer L11 Hyd 2U compares with the closest alternatives MinersDeals supplies on hashrate, power draw, efficiency and cooling.
| Model | Hashrate | Algorithm | Power | Efficiency | Cooling | Release |
|---|---|---|---|---|---|---|
| Bitmain Antminer L11 Hyd 2U | 35 Gh/s | Scrypt | 5775 W | 165 J/Gh | Hydro (liquid) cooling | December 2025 |
| Bitmain Antminer L11 Hyd 6U | 33 Gh/s | Scrypt | 5676 W | 172 J/Gh | Hydro (liquid) cooling | Late 2025 |
| Bitdeer SealMiner DL1 Hydro | 52.5 Gh/s | Scrypt | 7823 W | 149 J/Gh | Hydro (liquid) cooling | June 2026 |
| Bitdeer SealMiner DL1 Air | 25 Gh/s | Scrypt | 3725 W | 149 J/Gh | Air cooling | March 2026 |
Efficiency (joules per unit of hashrate) determines how long a machine stays profitable as network difficulty rises, while total power draw determines what electrical and cooling infrastructure you need per unit. A more efficient miner is not automatically the better purchase — price per terahash, availability and the cost of the cooling infrastructure it demands all feed into the decision.
If you are weighing two of these models against each other, send us your electricity rate, target quantity and site cooling type and we will model the comparison against real availability and pricing.
Pricing for the Bitmain Antminer L11 Hyd 2U can vary depending on quantity, availability, market conditions and fulfillment requirements. MinersDeals provides individual and volume quotes for qualified buyers, so we publish current pricing on request rather than as a fixed list price.
Buying multiple units? Ask about volume pricing.
Looking to purchase the Bitmain Antminer L11 Hyd 2U? MinersDeals helps individual buyers, mining operators and enterprise customers source specialized hardware. Submit your requirements to receive current availability and pricing.
Planning a larger deployment? Request pricing for 10, 50, 100 or more units. MinersDeals supports hardware procurement for mining farms, hosting providers and infrastructure operators, including staged delivery across multiple sites.
Scrypt coins — principally Litecoin and Dogecoin through merge mining, plus smaller Scrypt chains.
35 Gh/s at 5,775 W, about 165 J/Gh.
No. The 2U model connects to a facility coolant loop. The 6U variant is self-contained.
The same Scrypt work is submitted to both Litecoin and Dogecoin, so a single machine earns block rewards on both chains.
Bitmain has not published full dimensions and weight for this SKU in accessible documentation. Request the spec sheet from sales.
Tell us the quantity, destination and deployment timeline, and our team will come back with current availability and a quotation.